Cisco PWR-CC1-400WDC

Cisco C8300 1RU DC Power supply

In Stock
US $650.00
Add to cart Make offer
Product Highlights
Family
Switches
Brand
Cisco
Warranty
Lifetime (see details)
Availability
Usually Ships within 3-4 Days

Deploying enterprise edge routers in DC-powered environments — telecom central offices, remote service-provider facilities, or sites without reliable AC mains — demands a power supply purpose-built for those conditions. The Cisco PWR-CC1-400WDC is a 400-watt DC power supply module designed specifically for the Cisco Catalyst 8300 Series 1RU Edge Platforms.

Accepting a wide –40V to –72V DC input range, this PSU integrates seamlessly with standard –48V telecom battery plants and DC distribution systems. It delivers a clean, regulated 12V output at up to 33.5A, ensuring stable operation of the C8300 chassis and its installed modules. With 85% power efficiency, it minimizes thermal load and energy costs in facilities where every watt counts.

The PWR-CC1-400WDC is a hot-swappable, field-replaceable plug-in module that supports 1+1 redundancy in load-sharing mode when paired with a second power supply. This means you can replace a failed unit or perform planned maintenance without interrupting network services — critical for SD-WAN edge nodes and branch routers that must maintain continuous uptime. Compatible with the C8300-1N1S-4T2X, C8300-1N1S-6T, and select C8200 platforms, it is the go-to DC power option for Cisco's next-generation edge routing infrastructure.

Features & Benefits
Telecom-Grade DC Input

The PWR-CC1-400WDC accepts a –40V to –72V DC input range, making it fully compatible with standard –48V telecom battery plants and centralized DC power distribution systems. This wide input tolerance ensures stable operation even during battery discharge cycles or voltage fluctuations common in service-provider and central-office environments.

Hot-Plug Redundancy

Designed as a hot-swappable plug-in module, this power supply can be inserted or removed without powering down the chassis. When paired with a second PSU, the two units operate in 1+1 load-sharing mode, providing automatic failover and ensuring uninterrupted service during maintenance or a PSU failure.

High Efficiency Operation

At 85% power efficiency, the PWR-CC1-400WDC converts more input power into usable output while generating less waste heat. This reduces cooling requirements and energy costs — a meaningful advantage in dense deployments or facilities with constrained thermal budgets.

Field-Replaceable Design

As a field-replaceable unit (FRU), the PWR-CC1-400WDC simplifies spares management across distributed branch and edge sites. Network teams can stock a single DC PSU SKU and quickly swap units on-site, minimizing mean time to repair (MTTR) and reducing the need for specialized depot service.

Deployment Scenarios
Telecom Central Office / Service Provider POP

Central offices and points of presence typically run on –48V DC battery plants. The PWR-CC1-400WDC's –40V to –72V input range integrates directly with these DC distribution systems, powering Catalyst 8300 SD-WAN edge routers without requiring AC inverters or additional power conversion equipment.

Remote Branch with DC Power Infrastructure

Remote or industrial branch sites that rely on DC power sources — such as solar-battery systems or DC microgrids — benefit from a native DC power supply. The PWR-CC1-400WDC eliminates the AC conversion step, improving overall power-path efficiency and reducing points of failure.

Redundant PSU Upgrade or Replacement

For existing Catalyst 8300 1RU deployments that need a DC power supply replacement or a second PSU for 1+1 redundancy, the PWR-CC1-400WDC serves as a hot-swappable drop-in unit. It enables non-disruptive upgrades and ensures continuous operation during planned maintenance windows.

400W DC Power Output — Delivers reliable, regulated 12V/33.5A power to Cisco Catalyst 8300 1RU edge platforms
Wide DC Input Range (–40V to –72V) — Compatible with standard –48V telecom battery plants and central office environments
85% Power Efficiency — Reduces energy waste and lowers operating costs in always-on deployments
Hot-Plug, Redundant Design — Swap or replace the PSU without downtime for maximum service availability
1+1 Load-Sharing Redundancy — Pair two supplies for automatic failover and balanced power distribution
Terminal Block DC Input Connector — Secure, tool-fastened wiring for vibration-resistant DC installations
Field-Replaceable Unit — Simplifies maintenance and spares management across distributed branch sites
Broad Platform Compatibility — Supports C8300-1N1S-4T2X, C8300-1N1S-6T, C8200-1N-4T, and more
General
Manufacturer
Cisco
Part Number
PWR-CC1-400WDC
Product Type
Power Supply
Device Type
Power supply — hot-plug / redundant — plug-in module
Form Factor
Plug-in module (1RU)
Designed For
Cisco Catalyst 8300 and 8200 Series 1RU Edge Platforms
Power
Power Capacity
400W
Input Type
DC
Input Voltage Range
–40V to –72V DC
Input Current
13A – 7.25A
Output Ratings
12V / 33.5A
Output Hold-Up Time
2 ms
Power Supply Efficiency
85%
Redundancy
1+1 load-sharing
Connectivity
Input Connector
Terminal block (2-wire screw-type)
Power Cord Rating
15A, #14 AWG wire
Compatibility
Compatible Platforms
C8300-1N1S-4T2X, C8300-1N1S-6T, C8200-1N-4T, C8200L-1N-4T, C8200-UCPE-1N8
Compatibility Notes

Compatible Platforms

The PWR-CC1-400WDC is designed for the following Cisco Catalyst 8300 and 8200 Series Edge Platforms:

  • C8300-1N1S-4T2X (1RU, 2×10G + 4×1G WAN)
  • C8300-1N1S-6T (1RU, 6×1G WAN)
  • C8200-1N-4T
  • C8200L-1N-4T
  • C8200-UCPE-1N8

Note: This is a 1RU-form-factor power supply. It is not compatible with the 2RU C8300-2N2S models, which use the larger 650W DC supply (PWR-CC1-650WDC). The power supplies between 1RU and 2RU chassis are not interchangeable.

Wiring Requirements

  • DC input connector: Terminal block (2-wire screw-type)
  • Power cord rating: 15A, #14 AWG wire
  • Input polarity (facing unit, left to right): Positive (+), Negative (–)
Downloads & Resources
Frequently Asked Questions

Yes. The PWR-CC1-400WDC is a hot-plug, field-replaceable power supply module. You can insert or remove it without shutting down the Catalyst 8300 chassis, provided a second PSU is installed and operational for redundancy.

The Catalyst 8300 1RU platforms support dual redundant power supplies that operate in 1+1 load-sharing mode. Cisco documentation references AC/DC dual-PSU configurations as possible on the platform, but always consult the latest Cisco ordering guide and release notes for your specific IOS XE version to confirm mixed-mode support.

No. The PWR-CC1-400WDC is designed for the 1RU C8300 models (C8300-1N1S-4T2X and C8300-1N1S-6T). The 2RU C8300-2N2S models use a different, larger form-factor PSU such as the PWR-CC1-650WDC. The power supplies are not interchangeable between 1RU and 2RU chassis.

The PWR-CC1-400WDC accepts a –40V to –72V DC input range via a terminal block connector. It is designed for standard –48V telecom DC battery plants. Wiring must use 15A-rated, #14 AWG conductors per Cisco specifications.

No. The PWR-CC1-400WDC is a system-power DC PSU only. It does not provide a PoE power budget. If you need PoE capability, refer to Cisco's PoE-specific power supply options for the Catalyst 8300 platform.
Part Number Product Key Difference
PWR-CC1-400WAC Cisco C8300 1RU 400W AC Power Supply AC input version (100–240V AC) for sites with standard AC mains — same 400W capacity, different input type.
PWR-CC1-250WAC Cisco C8300 1RU 250W AC Power Supply Lower-wattage 250W AC option for C8300 1RU platforms with lighter power requirements.
PWR-CC1-650WDC Cisco C8300 2RU 650W DC Power Supply Higher-wattage 650W DC supply designed for the larger C8300-2N2S 2RU chassis — not interchangeable with 1RU models.
PWR-CC1-650WDCR Cisco C8300 2RU 650W DC NEBS Power Supply (Reverse Airflow) 650W DC supply with reverse airflow for NEBS-compliant 2RU deployments in telco central offices.